Case presentation
Discussion

ABSTRACT

 

Due to the recent increase in endovascular procedures, retained foreign bodies such as stents and catheters in vasculature have become a common and serious complication. Treatments for these complications vary depending on the acuity and stability of the foreign body in the vessel. We discuss a rare case of an adult found to have an incidental retained umbilical artery catheter in the aorta.

CASE PRESENTATION

A 25-year-old female with no past medical or surgical history presented to the emergency department with a complaint of intermittent epigastric and abdominal pulsation sensation that she had been experiencing for the prior year. An abdominal aorta ultrasound showed no evidence of aneurysm or dissection, but a 3.9-centimeter, echogenic tubular structure was found in the distal abdominal aorta consistent with a retained catheter fragment (Images 1 and 2). The patient reported that she was born premature at seven months at an outside hospital. Given her history and the ultrasound findings, there was high suspicion for a retained fragment of an umbilical catheter in her aorta. Vascular surgery was consulted. The patient was seen in clinic but was later lost to follow-up before further imaging and treatment.

 

Image 1
Transverse formal ultrasonographic view of an echogenic tubular structure (arrow) in the aorta.

 

Image 2
Longitudinal formal utrasonographic view of a 3.9 centimeters (cm), echogenic tubular structure with the distal tip located 1.7 cm from the bifurcation (arrow).

DISCUSSION

This case demonstrates an incidental finding of a retained umbilical artery catheter fragment in an adult patient’s aorta. There are several case reports of retained umbilical artery catheter fragments in neonates and infants, which resulted in thrombosis, infection, and embolization.1,2 This is the first known finding of a retained umbilical artery catheter found in an adult patient. Given the recent increase in endovascular procedures, retained foreign bodies such as stents, coils, guidewires, and catheters in vasculature have become a common and serious complication.3 The recommended treatment for acute and nonadherent foreign body is endovascular retrieval, which has a high success rate with minimal mortality. However, in the case of stable intravascular foreign bodies, which are adherent to the vessel wall, the benefits of removal such as decreasing the risk of thrombosis and further migration should be weighed against the risks. In those cases, leaving the foreign body in place is an option.4

 

CPC-EM Capsule

What do we already know about this clinical entity?

Intravascular retained foreign bodies as a result of endovascular procedures can have many complications, including thrombosis and infection.

What is the major impact of the image(s)?

This is the first known case of retained umbilical artery catheter fragment found in an adult.

How might this improve emergency medicine practice?

Incidental findings of stable intravascular foreign bodies in the emergency department can be managed with observation and referral to vascular surgery.

 

Footnotes

Section Editor: Rick A. McPheeters, DO

Full text available through open access at http://escholarship.org/uc/uciem_cpcem

Documented patient informed consent and/or Institutional Review Board approval has been obtained and filed for publication of this case report.

Address for Correspondence: Daniel Quesada, MD, Kern Medical Center, Department of Emergency Medicine, 1700 Mount Vernon Ave., Bakersfield, CA 93306. Email: Rhabdo77k@gmail.com. 3:434 – 435

Submission history: Revision received April 18, 2019; Submitted June 30, 2019; Accepted July 23, 2019

Conflicts of Interest: By the CPC-EM article submission agreement, all authors are required to disclose all affiliations, funding sources and financial or management relationships that could be perceived as potential sources of bias. The authors disclosed none.

REFERENCES

1. Kotnis R, Salloum A, Hitchcock R. Retained umbilical artery catheter presenting as an umbilical abscess. Arch Dis Child Fetal Neonatal Ed. 2000;83(1):F77.

2. Dilli D, Özyazici E, Fettah N, et al. Rupture and displacement of umbilical arterial catheter: Bilateral arterial occlusion in a very low birth weight preterm. Arch Argent Pediatr. 2015;113(5):e283-5.

3. Whang G, Lekht I, Krane R, et al. Unintentionally retained vascular devices: improving recognition and removal. Diagn Interv Radiol. 2017;23(3):238-44.

4. Carroll MI, Ahanchi SS, Kim JH, et al. Endovascular foreign body retrieval. J Vasc Surg. 2013;57(2):459-63.